Calq international is a biomedical importer and distributor from Pakistan. We are mainly involved in the field of Interventional Cardiology and deals in reliable products of well known brand Rontis.
Cardiac Stents
Sirolimus – Eluting Biodegradable Polymer Stent System
“DES Re-discovered”

Abrax TM Sirolimus-Eluting Stent System is designed to perform successfully even in the
most demanding cases. The combination of Sirolimus’ antiproliferative action coupled
with Rontis’ biodegradable polymer and proven balloon catheter ensures effective
treatment of clinically difficult lesions with confidence. This essentially means that
patients who receive Abrax TMare a lot less likely to need another repeat procedure in the short term.
Abrax
Paclitaxel – Eluting Stent System
“Confidence meets DES”

Conceptualized as the specific solution for diabetic patients. PhoenixTM ensures
excellent stent deliverability and linear drug elution even in the most tortuous
vasculature. Highly effective medical treatment also for Peripheral Artery Disease.

Sirolimus

  • Suppresses neointimal growth without suppressing endothelialization
  • Reduces in-stent restenosis
  • Drug load 2.0 µg/mm2
Technical Data

Abrax TM Sirolimus – Eluting Biodegradable Polymer Stent System

Mode of exchange:
Rx
Baloon material / characteristic:
modified polyamide / semi-compliant
Guidewire compatibility (max):
0.014"
Guiding Catheter compatibility (min):
5F
Nominal Pressure:
6 bar
Rated Burst Pressure:
14-16 bar


Stent Specifications


Material:
Carbonized SS alloy
Strut thickness:
110 µm (average)
Metal / Artery Ratio:
13-15%
Crossing profile:
1.05mm


Polymer/Drug Specifications


Drug carrier polymer:
biodegradable
Polymer biodegradation period:
6 weeks
Polymer thickness:
ca. 5µm
Drug:
Sirolimus
Drug loading:
2.0µg/mm2


Sirolimus molecular structure
Biodegradable polymer

  • PLGA
  • Uniform and site-specific drug delivery
  • Thin layer 5 µm
  • Complete degradation into its monomer following the drug release within 6 weeks
  • Eliminating inflammation, stent thrombosis and MACE
Stent platform

  • Carbon C+ implanted surface for higher biocompatibility and reduced restenosis rate
  • Intra-cellular “sinusoidal links”
  • Open cell design ensures balance of radial strength and flexibility
  • Enhanced radiopacity
  • Optimal scaffolding as well as stent-to-wall apposition with superior acute gain

Balloon catheter platform

  • Lower inflation pressures
  • Homogenizes stent expansion
  • Hydrophilicity lowers friction optimizing deliverability
Sirolimus – Eluting Biodegradable Polymer Stent System
Paclitaxel – Eluting Stent System
“Confidence meets DES”

Conceptualized as the specific solution for diabetic patients. PhoenixTM ensures
excellent stent deliverability and linear drug elution even in the most tortuous
vasculature. Highly effective medical treatment also for Peripheral Artery Disease.
Phoenix Pico
Paclitaxel Drug

  • Inhibits cell proliferation and platelet aggregation
  • Controls cellular pathways activated in the early response to balloon dilatation
  • Reduces restenosis
  • 1.0 µg/mm2 drug loading
Technical Data

Phoenix TM Paclitaxel-Eluting Cobalt Chromium Stent System

Mode of exchange:
Rx
Baloon material / characteristic:
modified polyamide / semi-compliant
Guidewire compatibility (max):
0.014"
Usable Catheter Length:
140 cm
Guiding Catheter compatibility (min):
5F
Radiopaque markers:
2, Platinum – Iridium
Nominal Pressure:
8 bar
Rated Burst Pressure:
16 bar
Coating:
Hydrophilic, HiFlow


Stent Specifications


Material:
Cobalt Chromium
Strut thickness:
65-74µm
Crossing profile:
0.021"


Polymer/Drug Specifications


Drug carrier polymer:
Polysulfone
Polymer thickness:
ca. 5.4µm
Drug:
Paclitaxel
Drug loading:
1.0µg/mm2
Total shelf life:
2 years


Paclitaxel – Eluting Stent System


CoCr stent platform

  • Very low profile
  • Ultra-low strut thickness 65-74 µm
  • Intra-cellular “sinusoidal links”
  • High radial strength
  • Excellent flexibility
  • Enhanced radiopacity
Polysulfone polymer

  • Ensures controlled and uniform drug release
  • Highly biocompatible
  • Hydrophilic surface
  • Mechanical stability
  • Good adherence to the stent platform
  • High aging stability
Paclitaxel molecular structure
Paclitaxel – Eluting Stent System
“Confidence meets DES”

Conceptualized as the specific solution for diabetic patients. PhoenixTM ensures
excellent stent deliverability and linear drug elution even in the most tortuous
vasculature. Highly effective medical treatment also for Peripheral Artery Disease.

Cobalt – Chromium Stent System
“Performance delivered with success”

Designed to perform and quickly become the stent of choice even in the most
challenging cases of interventional cardiologists daily practice. The trusted
CoCr stent alloy is used to ensure outstanding radial strength, high radiocapacity
and biocompatibility providing enchanced trackability and improved pushability,
as well. Its high average burst pressure indicates good stent-to-wall apposition.
Leader Plus
New folding pleating technology

  • Fully automated tri-folding process for increased flexibility, lower balloon primary crossing profile and enhanced rewrap for minimal secondary profile
  • Partially encapsulated stent with balloon material due to stent retention technology combining heat and pressure
Technical Data

Leader Plus TM Cobalt – Chromium Stent System

Mode of exchange:
Rx
Baloon material / characteristic:
modified polyamide / semi-compliant
Guidewire compatibility (max):
0.014"
Usable Catheter Length:
140 cm
Guiding Catheter compatibility (min):
5F
Radiopaque markers:
2, Platinum – Iridium
Nominal Pressure:
8 bar
Rated Burst Pressure:
16 bar
Coating:
Hydrophilic, HiFlow


Stent Specifications


Material:
Cobalt Chromium
Strut thickness:
78µm for small vessels
90µm for medium vessels
Design:
multi – cellular waveform type
SV version (small vessels) (Ř2.25-2.75mm)
MV version (medium vessels) (Ř3.00-4.00mm)
Elastic recoil:
< 4.6%
Foreshortening:
< 4.6%
Metal / Artery Ratio:
13-17%
Total shelf life:
3 years
Cobalt – Chromium Stent System


New multicenter ELPIS II Registry ongoing
        New soft tip
  • Low profile 0.016?, short and tapered atraumatic soft tip facilitates easier access across the tightest lesion
Hybrid cell design
Innovative stent delivery system

  • Low profile reinforced shaft design for improved pushability and trackability
  • Rontis’ proprietary hydrophilic coating, HiFlow, ensuring low friction forces
  • Redesigned semi-compliant balloon providing homogeneous expansion and precise stent deployment
  • 2, Platinum-Iridium marker bands for lower crossing profile and precise positioning
  • No dog-boning effect
  • Closed cell ends for good anchoring and open cell mid-section for low metal-to-artery ratio
  • 2.25 – 2.75mm Small vessel design
  • 3.00 – 4.00mm Medium vessel design
Semi-Compliant Balloon Catheter
“The perfect choise for all lesions”

Combines a new low profile, tapered tip design with a lower profile shaft.
New Hydrophilic coating ensures greater lubricity to cross tight and tortuous
anatomy with even greater confidence.
Europa Ultra
Improved trackability
Technical Data

Europa Ultra TM Semi-Compliant Balloon Catheter

Mode of exchange:
Rx
Baloon material / characteristic:
modified polyamide / semi-compliant
Usable Catheter Length:
140 cm
Guiding Catheter compatibility (min):
5F
Radiopaque markers:
2, Platinum – Iridium
Distal shaft:
2.4F (Ř2.00mm)
2.5F (Ř2.25-3.50mm)
2.9F (Ř4.00-5.00mm)
Hypotube:
2.0F
Crossing profile:
0.021"
Guidewire compatibility (max):
0.014"
Nominal pressure:
8 bar
Rated Burst Pressure:
16 bar
Average Burst Pressure:
26 bar (Ř2.00-3.50 mm)
23 bar (Ř4.00-5.00 mm)
Coating:
Hydrophilic, Hiflow
Total shelf life:
3 years
Semi-Compliant Balloon Catheter


  • Ultra low 0.016" entry profile of Rontis’ soft, short and tapered atraumatic tip ensures safe access
  • Ultra-low 0.021" crossing profile
  • Proprietary ironing process ensures ideal refoldability
  • Tip-to-wire conformance along with controlled steering from hand-to-tip for excellent torqueability
  • Rontis’ proprietary high performance materials contribute to lower shaft profiles
  • Integrated shaft-hypotube transition ensures 1:1 pushability
  • Laser-bonding technology at critical flex points provides a balance of seamless and flexible transition
  • 2, Platinum-Iridium marker bands presenting the distal and proximal balloon shoulders provide higher radiopacity
  • Controlled balloon expansion for accurate dilatation of arteries, therefore minimizing the possibility for artery damage
Lubricity

  • Rontis’ proprietary hydrophilic coating, HiFlow ensures smoother navigation through even the most challenging and tortuous vasculature
Chronic Total Occlusions Balloon Catheter
“Lowest Profiles with Improved pushability for even the most challenging cases”

Designed to achieve greater crossability even in the most complex chronic occlusions.
The combination of the low crossing profile, tapered tip technology and extra support
shaft can traverse even the most difficult occlusions with the least resistance.
Europa Ultra CTO
Improved trackability
Technical Data

Europa Ultra CTO TM Chronic Total Occlusions Balloon Catheter

Mode of exchange:
Rx
Baloon material / characteristic:
modified polyamide / semi-compliant
Usable Catheter Length:
140 cm
Guiding Catheter compatibility (min):
5F
Radiopaque markers:
1, Platinum – Iridium
Distal shaft:
2.4F
Hypotube:
2.0F
Crossing profile:
0.020"
Guidewire compatibility (max):
0.014"
Nominal pressure:
8 bar
Rated Burst Pressure:
16 bar
Average Burst Pressure:
28 bar
Coating:
Hydrophilic, Hiflow
Total shelf life:
3 years
Chronic Total Occlusion Dilatation Catheter

  • Ultra-low 0.016" soft yet durable tip form is designed to cross Chronic Total Occlusions
  • Ultra-low 0.020" crossing profile
  • Central Platinum-Iridium marker band for high radiopacity and lower balloon distal profiles for enhanced crossability
  • Rontis’ proprietary material blend ensures ultra low profile and extremely durable balloons
  • High pressure capability, providing extreme resistance to potential puncture
  • Safely inflated up to 24 bar
  • Homeogeneous expansion throughout the entire balloon length
  • Rontis’ proprietary hydrophilic coating, HiFlow for smoother navigation through the most challenging vasculature
  • Low profile shaft, ensuring more penetration power
  • Fully integrated hypotube-shaft transition optimizes pushability
Non-Compliant Balloon Catheter
” The superior high force for the demanding Interventionalist ”

Low profile, high pressure angioplasty catheters designed to be used in dilating
the unyielding fibrocalcified lesions with a high pressure application providing
controlled expansion, as well. The use of Europa Ultra NCTM for post-dilatation
of DES/or BMS optimizes stent-to-wall apposition, reduces edge effects and minimizes
vessel wall damage post stenting, even in stiff fibrotic lesions
Europa Ultra NC
Improved trackability
Technical Data

Europa Ultra NC TM Non-Compliant Balloon Catheter

Mode of exchange:
Rx
Baloon material / characteristic:
modified polyamide / semi-compliant
Usable Catheter Length:
140 cm
Guiding Catheter compatibility (min):
5F
Radiopaque markers:
2, Platinum – Iridium
Distal shaft:
2.4F (Ř 2.00mm)
2.5F (Ř 2.25-3.50mm)
2.9F (Ř 4.00mm)
Hypotube:
2.0F
Crossing profile:
0.021"
Guidewire compatibility (max):
0.014"
Nominal pressure:
10 bar
Rated Burst Pressure:
20 bar
Average Burst Pressure:
25 bar
Coating:
Hydrophilic, Hiflow
Total shelf life:
3 years
Non-Compliant Balloon Catheter
  • Non-Compliant design resisting deformation when subjected to pressure
  • Controlled minimal balloon growth -5% between NP & RBP for flat compliance
  • High pressure catheter (RBP 20 bar)
  • Optimal accuracy is ensured even under high dilatation forces while maintaining dimensional stability
  • Ultra-low 0.016? tip profile
  • Soft, short and tapered atraumatic tip
  • Rontis’ proprietary balloon material blend ensures decreased wall thickness
  • 0.021? crossing profile
  • Rontis’ proprietary hydrophilic coating, HiFlow for enhanced lubricity
  • Homogeneous balloon expansion
  • Tri-folding balloon technology
0.014" Guidwire
“Guiding with a new first choise”

Designed to offer the performance and deliverability required when accessing
and crossing tortuous anatomy. Lotus IITM Guidewire is indicated for a broad range
of coronary applications and can thus serve as ideal first choice wire.vailable to cross all lesions.
Lotus II
Technical Data

Lotus II TM 0.014" Guidewire

Design:
Stainless steel core-to-tip
Tip load:
0.30 – 0.45 – 0.60 gr
Tip shape:
Straight (S), “J” Shaped (J)
Radiopaque coil distal tip:
30 mm
Outside diameter:
0.014"
Coating:
Hydrophilic
Length:
195/300 cm
Support:
Normal (N), Extra (X)
0.014" Guidwire
  • Stainless steel design, reducing core twisting and improving resistance to wire deformation (excellent torqueability)
  • Special ridge transition, minimizing tip prolapse
  • Hydrophilic coating providing better trackability
  • Excellent tip shape retention
  • PTFE coated shaft
  • Gentle and atraumatic navigation
  • Optimal radiopacity
  • Variations in tip stiffness provides a step up approach to penetrate lesions. Tip load is available in 0.60 grams (standard), 0.45 grams (intermediate), 0.30 grams (floppy)
  • Also used in peripheral applications, such as below-the-knee cases
The new Lotus II TM Guidewire is engineered with a smooth and stable transition between core and tip so as to ensure optimal handling characteristics.
  • Normal support provides a balance of flexibility and support for optimal wire delivery and enough support to deliver most interventional devices
  • Extra support facilitates more challenging cases benefiting from increased rail support
0.014" CTO Guidwire
“Enhanced technology to cross the impossible”

Achieves excellent crossability and distal access so as to traverse even the
most challenging chronic total occlusive lesions.
Lotus XP
Technical Data

Lotus II TM 0.014" Guidewire

Design:
Stainless steel core-to-tip
Tip load:
3.0 – 12.0 gr
Tip shape:
Straight (S), “J” Shaped (J)
Tip design:
Dome (D), Wedge (W)
Radiopaque coil distal tip:
30 mm
Outside diameter:
0.014"
Coating:
Hydrophilic
Length:
195/300 cm
Support:
Normal (N)
0.014" CTO Guidwire
  • Extra supportive stainless steel core enhancing pushability and deliverability
  • Progressive ramp up in tip support so as to treat highly stenosed occlusions
  • Tip load: 3.0, 4.5, 6.0, 9.0, 12 gr
  • Powerful torque control for sub selective navigation
  • Hydrophilic coating, maintaining lubricity during the longest of cases
  • Optimal radiopacity
  • Gentle and atraumatic navigation
  • Also used in peripheral applications, such as below-the-knee cases
Lotus XP TM Guidewire is the latest addition to Rontis’ range of Guidewires. The interventionalist can select from a wide range of tip configurations so that even the most challenging of lesions can be accessed.